Inquiry Now
Leave Your Message

Three Phase Digital Combined Meter from China Suppliers - High-Performance Factory Solution for Power Monitoring

,

Expanded Technical Specification: Three-Phase Digital Combined Meter

,

The Three-Phase Digital Combined Meter, designed by leading China suppliers, is an advanced, multi-parameter electronic measuring device tailored for real-time monitoring and display of essential electrical parameters in three-phase AC power systems. Ideal for use in industrial distribution cabinets, control panels, substation monitoring stations, and commercial power management systems, this versatile all-in-one instrument effectively replaces multiple standalone meters. This not only minimizes equipment footprint but also simplifies wiring and reduces overall system deployment costs, making it a smart choice for factories and businesses looking for efficient power management solutions.

,

    Product Overview

    Its core application focuses on the accurate measurement and visualization of three-phase current, three-phase voltage, and grid frequency, with scalable parameter options to meet diverse user requirements for power system diagnostics and efficiency analysis.

    Core Measurement Capabilities

    The Instrument offers flexible, configurable measurement ranges to accommodate both three-phase three-wire (3P3W) and three-phase four-wire (3P4W) system topologies, with the following parameter coverage:

    • Current Measurement: Accurate RMS current detection for all three phases — IA (Phase 1 Current), IB (Phase 2 Current), and IC (Phase 3 Current).
    • Voltage Measurement: Comprehensive RMS voltage monitoring including phase voltages (UA = L1-N, UB = L2-N, UC = L3-N) and line-to-line voltages (UAB = L1-L2, UBC = L2-L3, UCA = L3-L1), totaling six independent voltage channels.
    • Extended Parameter Options: Available in multiple variants with additional measurement functions to suit specific application needs.

    🔵 Basic Variant

    Grid frequency measurement (typically 45–65 Hz)

    🟡 Mid-Range Variant

    Frequency + power factor (capacitive/inductive range) measurement

    🟢 Advanced Variant

    Frequency + active power (W/kW/MW) measurement

    💡 This multi-parameter design enables the Instrument to replace a suite of standalone devices — including three-phase ammeters, voltmeters, frequency meters, power factor meters, and active power meters — streamlining system architecture and improving monitoring efficiency.
    Key Technical Features & Advantages
    🔩

    Advanced SMT Construction

    State-of-the-art Surface Mount Technology delivers a compact, dense circuit layout that minimizes internal signal interference, enhances structural stability, and provides superior reliability in harsh industrial environments with high vibration, temperature fluctuations, or EMI.

    📐

    True RMS Measurement with AC Sampling

    High-precision AC sampling with a true RMS algorithm ensures accurate readings regardless of waveform distortion caused by non-linear loads such as VFDs, rectifiers, switching power supplies, or arc furnaces — eliminating errors from distorted waveforms.

    ⚙️

    Programmable Display Scaling & Wide CT Compatibility

    User-programmable display multiplier enables seamless calibration to match CT ratios with primary current ratings from 5 A to 10,000 A. Compatible with standard 1 A or 5 A secondary CT output, allowing direct display of primary system current values on-site.

    Technical Parameters

    Technical Parameters Index
    Input Network Three-phase three-wire, three-phase four-wire
    Voltage Rated Value AC 0~500V
    Over Load Consistent: 1.2× ; Instantaneous: 2× / 30s
    Consumption <0.5VA (each phase)
    Impedance >500kΩ
    Current Rated Value AC 1A, 5A
    Over Load Consistent: 1.2× ; Instantaneous: 2× / 1s
    Impedance <2mΩ
    Frequency 45–65 Hz
    Output Communication Output Mode RS485
    Protocol MODBUS RTU
    Baud Rate 1200, 2400, 4800, 9600
    Technical Parameters Index
    Output Analog Quantity Channel Quantity 4 channels
    Output Mode 0~20mA, 4~20mA
    Load Ability ≤400W
    Switching Value Channel Quantity 4 channels
    Output Mode Normally open relay contact output
    Contact Capability AC 240V / 0.1A
    Switching Value Input Four channel dry contact input modes
    Display Mode LED (Red)
    Measuring Accuracy Voltage, Current ± (0.5%FS + one digit)
    Active Power, Reactive Power ± (0.5%FS + one digit)
    Frequency ± 0.1 Hz
    Power Factor ± 0.01 PF
    Source Scope AC 220V 50/60Hz or AC/DC 85~265V
    Consumption <5VA
    Safety Withstand Voltage Input and Source >2kV 50Hz / 1min
    Input and Output >1kV 50Hz / 1min
    Output and Source >2kV 50Hz / 1min
    Insulating Resistance Any two of input, output, source, casing >20MΩ
    Environment Temperature Operation: -10°C to 50°C
    Storage: -25°C to 70°C
    Humidity <85%RH, free of wet and corrosive gas
    Elevation ≤3000m

    Frequently Asked Questions

    What network topologies does this instrument support?
    The instrument supports both three-phase three-wire (3P3W) and three-phase four-wire (3P4W) system topologies, making it compatible with a wide range of industrial and commercial power distribution systems.
    What is the difference between the Basic, Mid-Range, and Advanced variants?
    The Basic Variant measures grid frequency (45–65 Hz) in addition to current and voltage. The Mid-Range Variant adds power factor (capacitive/inductive) measurement. The Advanced Variant further includes active power measurement in W/kW/MW, providing the most comprehensive monitoring capability.
    Why is True RMS measurement important for modern power systems?
    Modern power systems often include non-linear loads such as variable frequency drives, rectifiers, and switching power supplies that distort the current and voltage waveforms. True RMS measurement accurately calculates the actual power values regardless of waveform shape, whereas average-value sensing meters can produce significant errors in such environments.
    What current transformer (CT) ratios are compatible with this instrument?
    The instrument is compatible with standard CTs rated for 1 A or 5 A secondary output, and supports primary current ratings from 5 A up to 10,000 A. The user-programmable display multiplier allows the display to show primary system current values directly, eliminating manual ratio calculations.
    What communication interfaces and protocols does the instrument support?
    The instrument features an RS485 communication output using the MODBUS RTU protocol. It supports baud rates of 1200, 2400, 4800, and 9600 bps, enabling easy integration into existing SCADA systems, PLCs, and building management systems.
    What are the power supply requirements and environmental operating conditions?
    The instrument can be powered by AC 220V 50/60Hz or a wide-range AC/DC 85~265V supply, consuming less than 5VA. It operates reliably within a temperature range of -10°C to 50°C, at humidity levels below 85%RH (non-condensing), and at altitudes up to 3,000 meters above sea level.