Single Phase Multifunctional Power Instrument
Product Overview
Many kinds of extended function modules for choosing: one-channel analog quantity (0~20mA/4~20mA)output can realize the transmitting output function of electrical quantity; two-channel switching value input and two-channel switching value output to realize the local or long-range switch signal monitoring and control output function (function of“ remote signaling” and “ remote control” ).The instrument can directly replace conventional power transmitter, measuring indicating instrument, electric energy measuring instrument and the related auxiliary unit. With modular structural design, users can choose the most economical functional configuration according to the actual requirement, which is highly cost-effective.
Technical Parameters
|
Technical parameters |
Index |
||||||
|
Input |
Net work |
Single phase |
|||||
|
Voltage |
Rated value |
AC 0~500v |
|||||
|
Over load |
Consistent 1.2 times iostaotaoeos,2 times /30s |
||||||
|
Consumption |
<0.5VA(each phase) |
||||||
|
Impedance |
>500k0 |
||||||
|
Current |
Rated value |
AC 1A, SA |
|||||
|
Over load |
Consistent:1 .2 times mstaotaneocs,2 times /1s |
||||||
|
Impedance |
<2mΩ |
||||||
|
Frequency |
45-65Hz |
||||||
|
Output |
Communication |
Output mode |
RS485 |
||||
|
Protocol |
MODBUS_RTU |
||||||
|
Baud rate |
1200,2400,4800, 9600 |
||||||
|
Analog quantity |
Channel quantity |
1 channels |
|||||
|
Output mode |
0-20mA, 4-20mA |
||||||
|
Load ability |
≤400Ω |
||||||
|
Switching value |
Channel quantity |
2 channels |
|||||
|
Output mode |
Normally open relay contact output |
||||||
|
Contact capability |
AC 250V/5A, DC 30V/5A |
||||||
|
Switching value input |
2 channels |
||||||
|
Display mode |
LED(Red) |
||||||
|
Measuring accuracy |
Voltage, current |
土(0. 5%FS+one digit) |
|||||
|
Active power, reactive power |
士(0. 5%FS+one digit) |
||||||
|
Frequency |
士0.1 Hz |
||||||
|
Power factor |
士0.0 1PF |
||||||
|
Active energy |
士 0. 5%(only for reference, not for meterage) |
||||||
|
Reactive energy |
土1.0 %(only for reference , not for meterage) |
||||||
|
Source |
Scope |
AC 220V,50/60Hz |
|||||
|
Consumption |
<5VA |
||||||
|
Safety |
Withstand voltage |
Input and sou 「 se |
>2kv50Hz/1min |
||||
|
Input and output |
>1kv50Hz/1mm |
||||||
|
Output and source |
>2kv50Hz/1mm |
||||||
|
insulating ,resistance |
Any two of input, output, source, casing>20MO |
||||||
|
Environment |
Temperature |
Operation, -10~50°C |
|||||
|
Storage, -25~70°C |
|||||||
|
Humidity |
<85%RH, free of wet and corrosive gas |
||||||
|
Elevation |
≤3000m |
||||||











