Inquiry Now
Leave Your Message
SFN-9K6-3UI Digital Combined Meter
Digital Meter

SFN-9K6-3UI Digital Combined Meter

Expanded Technical Specification: SFN-9K6-3UI Digital Combined Meter

The SFN-9K6-3UI Three-Phase Digital Combined Meter (hereafter referred to as "the Meter") is a high-performance electronic measuring instrument engineered for real-time monitoring and indication of key electrical parameters in three-phase AC power systems. Optimized for industrial control panels, distribution cabinets, and power monitoring stations, this compact device delivers precise, reliable data acquisition to support system diagnostics, load management, and operational efficiency.

    Product Overview

    Core Measurement Capabilities
    The SFN-9K6-3UI Meter is configured to capture critical voltage and current parameters across three-phase systems, with flexible measurement range options to accommodate diverse application requirements:
    ● Current Measurement: Accurately tracks RMS current values for all three phases, denoted as IA (Phase 1 Current), IB (Phase 2 Current), and IC (Phase 3 Current).
    ● Voltage Measurement: Offers two selectable voltage monitoring modes to match three-phase three-wire (3P3W) or three-phase four-wire (3P4W) system topologies:
    1. Phase Voltage Mode: Measures RMS phase voltages UA (Phase 1 Voltage), UB (Phase 2 Voltage), and UC (Phase 3 Voltage).
    2. Dual Voltage Mode: Captures both RMS phase voltages (UA, UB, UC) and RMS line-to-line voltages (UAB = L1-L2, UBC = L2-L3, UCA = L3-L1), totaling six independent voltage measurement channels.

    Key Technical Features & Advantages
    1. Advanced Manufacturing & Circuit DesignThe Meter utilizes Surface Mount Technology (SMT) for component assembly, resulting in a highly compact, dense circuit layout. This design minimizes internal signal interference, enhances structural stability, and delivers superior operational reliability—even in harsh industrial environments with high vibration, temperature fluctuations, or electromagnetic interference (EMI).

    2. High-Precision AC Sampling & RMS MeasurementEquipped with a dedicated AC sampling module and true RMS (Root Mean Square) measurement algorithm, the Meter ensures accurate parameter readings regardless of waveform distortion caused by non-linear loads (e.g., variable frequency drives, rectifiers, or switching power supplies). This feature eliminates measurement errors common in average-value sensing meters, making it ideal for distorted power system environments

    3. Programmable Display Scaling & Wide CT CompatibilityThe Meter’s programmable display multiplier function allows users to calibrate the device to match the ratio of external current transformers (CTs) with primary current ratings ranging from 5 A to 10,000 A. This flexibility enables direct, scaled display of primary system currents on the Meter’s local screen, eliminating the need for manual ratio calculations and simplifying on-site data interpretation for field personnel

    Technical Parameters

    Technical parameters

    Index

    Input

    Net work

    Three-phase three-wire, three-phase four-wire

    Voltage

    Rated value

    AC 0~500v

    Over load

    Consistent 1.2 times iostaotaoeos,2 times /30s

    Consumption

    <0.5VA(each phase)

    Impedance

    >500k0

    Current

    Rated value

    AC  1A, SA

    Over load

    Consistent:1 .2 times mstaotaneocs,2 times /1s

    Impedance

    <2mΩ

    Frequency

    45-65Hz

    Output

    Communication

    Output mode

    RS485

    Protocol

    MODBUS_RTU

    Baud rate

    1200,2400,4800, 9600

    Analog quantity

    Channel quantity

    4 channels

    Output mode

    0-20mA, 4-20mA

    Load ability

    ﹤400Ω

    Switching value

    Channel quantity

    4 channels

    Output mode

    Normally open relay contact output

    Contact capability

    AC 240V/0.1A

    Switching value input

    4 channel dry contact input modes

    Display mode

    LED(Red)

    Measuring accuracy

    Voltage, current

    土(0. 5%FS+one digit)

    Active power, reactive power

    士(0. 5%FS+one digit)

    Frequency

    士0.1 Hz

    Power factor

    士0.0 1PF

    Source

    Scope

    AC 220V,50/60Hz

    Consumption

    <5VA

    Safety

    Withstand voltage

    Input and sourse

    >2kv50Hz/1min

    Input and output

    >1kv50Hz/1mm

    Output and source

    >2kv50Hz/1mm

    insulating ,resistance

    Any two of input, output, source, casing>20MO

    Environment

    Temperature

    Operation, -10~50°C

    Storage, -25~70°C

    Humidity

    <85%RH, free of wet and corrosive gas

    Elevation

    ≤3000m