Inquiry Now
Leave Your Message

SFM472 Series Three-Phase Multifunction Meter from China Suppliers | Reliable Factory Solutions for Power Monitoring

Advanced Technical Specification: SFM472 Series Three-Phase Multifunctional DIN-Rail Meter

The SFM472 series three-phase multifunctional DIN-rail meter is an advanced electrical monitoring solution designed for efficient integration in three-phase four-wire (3P4W) power grid systems. Ideal for commercial, industrial, and utility-scale applications, this compact DIN-rail mounted meter provides accurate, real-time measurements of essential power parameters. Proudly manufactured in China, it serves as a vital component for modern power monitoring and management systems, meeting the needs of suppliers and factories looking for reliable performance and quality.

    Product Description

    Core Measurement Capabilities

    The SFM472 series meter is calibrated to provide accurate readings of key electrical parameters, supporting both balanced and unbalanced load conditions:

    Voltage

    Line-to-line (L1-L2, L1-L3, L2-L3) and line-to-neutral (L1-N, L2-N, L3-N) RMS voltage monitoring.

    Current

    Precise RMS current measurement individually monitored across all three phases.

    Power

    Active power, reactive power, and apparent power analysis (per phase and total system values).

    Frequency

    Continuous detection and tracking of power grid frequency fluctuations.

    Energy Metering

    Import (consumed) and export (fed-back) active/reactive energy with cumulative metering functionality.

    System Integration & Application Flexibility

    Designed for versatility, the SFM472 series meter caters to dual operational modes to meet diverse on-site requirements:

    1

    Local Display Function

    The meter features an on-board display that provides real-time visualization of measured parameters, enabling field personnel to conduct quick spot checks and verify system performance without additional equipment.

    2

    Centralized Measurement & Control System Integration

    Beyond local monitoring, the meter’s detection data can be seamlessly transmitted to industrial control equipment (such as PLCs, RTUs, and SCADA systems) and host computers via standard communication protocols. This enables a unified measurement network supporting remote data acquisition, real-time load analysis, energy auditing, and automated power management.

    With its robust measurement precision, compact DIN-rail form factor, and flexible integration capabilities, the SFM472 series meter is ideally suited for real-time power monitoring in 3P4W systems across manufacturing facilities, commercial buildings, data centers, and utility substations.

    Technical Parameters

    Parameters Index / Specification
    Input Voltage Voltage (Un): 3*57.7/100…240/415VAC
    Voltage range: 0.8Un - 1.15Un
    Current Directly connected: 0.25 - 5(80) A
    Overcurrent withstand: 30Imax for 0.01s
    Frequency 50 / 60Hz
    Wiring Connecting capacity: 16 to 25 mm²
    Display Display: LCD with white backlight
    Max reading: 999999 kWh
    Accuracy Active energy: Class 1, Class B
    Output Communication Interface: RS485
    Protocol: Modbus RTU
    Pulse Pulse constant: 800 imp/kWh
    Power Consumption < 2W / 10VA
    Withstand AC Voltage 4kV / 1 min
    DC Impulse 6kV - 1.2µs waveform
    Climate Environment Temperature Operating temperature: -25°C ~ +55°C
    Storage temperature: -40°C ~ +70°C
    Humidity ≤ 95% non-condensing, no corrosive gas
    Altitude ≤ 2000m
    Environment Classes Mechanical environment: M1
    Electromagnetic environment: E2

    Frequently Asked Questions

    What primary electrical parameters does the SFM472 series meter measure?

    The SFM472 measures line-to-line and line-to-neutral RMS voltage, 3-phase RMS current, active/reactive/apparent power (both per phase and total), grid frequency, and cumulative bidirectional active and reactive energy (import and export).

    What communication protocols and interfaces are supported?

    The device features an RS485 communication interface using the industry-standard Modbus RTU protocol, facilitating smooth connection to PLCs, RTUs, SCADA platforms, and building management systems.

    What is the measurement accuracy and rating standard?

    The meter complies with Class 1 (IEC) and Class B active energy measurement standards, delivering high precision for energy auditing, sub-metering, and industrial utility control.

    What current range and wiring terminal sizes does the meter support?

    It features direct connection capabilities supporting 0.25 - 5(80) A with an overcurrent withstand of 30Imax for 0.01s. The connection terminal capacity accommodates cable gauges from 16 to 25 mm².

    Under what environmental conditions can the SFM472 operate?

    The SFM472 operates reliably within a temperature range of -25°C to +55°C, handles relative humidity up to 95% (non-condensing), functions at altitudes up to 2000m, and meets M1 mechanical and E2 electromagnetic environment classifications.