SFM472 Series Three-Phase Multifunction Meter from China Suppliers | Reliable Factory Solutions for Power Monitoring
Product Description
The SFM472 series meter is calibrated to provide accurate readings of key electrical parameters, supporting both balanced and unbalanced load conditions:
Voltage
Line-to-line (L1-L2, L1-L3, L2-L3) and line-to-neutral (L1-N, L2-N, L3-N) RMS voltage monitoring.
Current
Precise RMS current measurement individually monitored across all three phases.
Power
Active power, reactive power, and apparent power analysis (per phase and total system values).
Frequency
Continuous detection and tracking of power grid frequency fluctuations.
Energy Metering
Import (consumed) and export (fed-back) active/reactive energy with cumulative metering functionality.
Designed for versatility, the SFM472 series meter caters to dual operational modes to meet diverse on-site requirements:
Local Display Function
The meter features an on-board display that provides real-time visualization of measured parameters, enabling field personnel to conduct quick spot checks and verify system performance without additional equipment.
Centralized Measurement & Control System Integration
Beyond local monitoring, the meter’s detection data can be seamlessly transmitted to industrial control equipment (such as PLCs, RTUs, and SCADA systems) and host computers via standard communication protocols. This enables a unified measurement network supporting remote data acquisition, real-time load analysis, energy auditing, and automated power management.
Technical Parameters
| Parameters | Index / Specification | |
|---|---|---|
| Input | Voltage |
Voltage (Un): 3*57.7/100…240/415VAC Voltage range: 0.8Un - 1.15Un |
| Current |
Directly connected: 0.25 - 5(80) A Overcurrent withstand: 30Imax for 0.01s |
|
| Frequency | 50 / 60Hz | |
| Wiring | Connecting capacity: 16 to 25 mm² | |
| Display |
Display: LCD with white backlight Max reading: 999999 kWh |
|
| Accuracy | Active energy: Class 1, Class B | |
| Output | Communication |
Interface: RS485 Protocol: Modbus RTU |
| Pulse | Pulse constant: 800 imp/kWh | |
| Power Consumption | < 2W / 10VA | |
| Withstand | AC Voltage | 4kV / 1 min |
| DC Impulse | 6kV - 1.2µs waveform | |
| Climate Environment | Temperature |
Operating temperature: -25°C ~ +55°C Storage temperature: -40°C ~ +70°C |
| Humidity | ≤ 95% non-condensing, no corrosive gas | |
| Altitude | ≤ 2000m | |
| Environment Classes |
Mechanical environment: M1 Electromagnetic environment: E2 |
|
Frequently Asked Questions
What primary electrical parameters does the SFM472 series meter measure?
The SFM472 measures line-to-line and line-to-neutral RMS voltage, 3-phase RMS current, active/reactive/apparent power (both per phase and total), grid frequency, and cumulative bidirectional active and reactive energy (import and export).
What communication protocols and interfaces are supported?
The device features an RS485 communication interface using the industry-standard Modbus RTU protocol, facilitating smooth connection to PLCs, RTUs, SCADA platforms, and building management systems.
What is the measurement accuracy and rating standard?
The meter complies with Class 1 (IEC) and Class B active energy measurement standards, delivering high precision for energy auditing, sub-metering, and industrial utility control.
What current range and wiring terminal sizes does the meter support?
It features direct connection capabilities supporting 0.25 - 5(80) A with an overcurrent withstand of 30Imax for 0.01s. The connection terminal capacity accommodates cable gauges from 16 to 25 mm².
Under what environmental conditions can the SFM472 operate?
The SFM472 operates reliably within a temperature range of -25°C to +55°C, handles relative humidity up to 95% (non-condensing), functions at altitudes up to 2000m, and meets M1 mechanical and E2 electromagnetic environment classifications.