Multifunctional Power Instrument LCD: China Suppliers & Factory for Accurate Electrical Monitoring Solutions
There are several different types of extended function modules to choose from: The four-channel analog quantity (0~20mA/4~20mA) output can transmit electrical quantity, while the four-channel switching value input and output can monitor and control local or long-range switch signals ("remote signaling" and "remote control"). The device may immediately replace a typical power transmitter, a measuring indication instrument, an electric energy measuring instrument, and any associated auxiliary units. With modular structural design, customers may select the most cost-effective functional configuration based on their specific requirements.
It is frequently utilized in applications such as energy management systems, supply and distribution network automation, district power control, and entire switchgear sets. It has the benefit of easy installation and maintenance. Sample wiring, small quantity, programmable input parameters, and networkable with various PLCs, industry control computer communications software.
-
⚡
4-Channel Analog Output
0~20mA / 4~20mA for transmitting electrical quantities -
🔁
Switching Value I/O
4-channel input & output for remote signaling and control -
🔌
Modular Design
Cost-effective configuration tailored to specific requirements -
🏭
Wide Application
Energy management, distribution automation & switchgear sets -
🔗
PLC Compatible
Networkable with PLCs and industrial control computer software
Technical parameters |
Index |
||
Input |
Network |
Three-phase three-wire, three-phase four-wire |
|
Voltage |
Rated value |
AC 0~500V |
|
Over load |
Consistent 1.2 times instantaneous, 2 times / 30s |
||
Consumption |
<0.5VA (each phase) |
||
Impedance |
>500kΩ |
||
Current |
Rated value |
AC 1A, 5A |
|
Over load |
Consistent: 1.2 times instantaneous, 2 times / 1s |
||
Impedance |
<2mΩ |
||
Frequency |
45–65Hz |
||
Output |
Electric energy |
Output mode |
Two-channel open-collector, optical coupling pulse output |
Pulse constant |
Active: 3200 imp/kWh |
||
Start |
On the condition of rated voltage, reference frequency and cosφ=1.0, when load operational current is 0.01In, it can start and measure the electric energy continuously. |
||
Creep |
When executing 115% rated voltage and no current in the current circuitry, the instrument has no electric energy accumulation and pulse output. |
||
Output |
Communication |
Output mode |
RS485 |
Protocol |
MODBUS_RTU |
||
Baud rate |
1200, 2400, 4800, 9600 |
||
Analog quantity |
Channel quantity |
4 channels |
|
Output mode |
0–20mA, 4–20mA |
||
Load ability |
<400Ω |
||
Switching value |
Channel quantity |
4 channels |
|
Output mode |
Normally open relay contact output |
||
Contact capability |
AC 240V / 2A |
||
Switching value input |
Four channel dry contact input modes |
||
Display mode |
LCD (Blue backlighting) |
||
Measuring accuracy |
Voltage, current |
± (0.5% FS + one digit) |
|
Active power, reactive power |
± (0.5% FS + one digit) |
||
Frequency |
± 0.1 Hz |
||
Power factor |
± 0.01 PF |
||
Active energy |
± 0.5% (only for reference, not for meterage) |
||
Reactive energy |
± 1.0% (only for reference, not for meterage) |
||
Source |
Scope |
AC 220V, 50/60Hz |
|
Consumption |
<5VA |
||
Safety |
Withstand voltage |
Input and source |
>2kV 50Hz / 1min |
Input and output |
>1kV 50Hz / 1min |
||
Output and source |
>2kV 50Hz / 1min |
||
Insulating resistance |
Any two of input, output, source, casing >20MΩ |
||
Environment |
Temperature |
Operation: -10 ~ 50°C |
|
Storage: -25 ~ 70°C |
|||
Humidity |
≤85% RH, free of wet and corrosive gas |
||
Elevation |
≤3000m |
||
Function & Shape / Model |
Measure & Display |
Shape Code (Figure Inside) |
Selected Additional Functions |
||||||||||||||||||||
Phase Voltage V |
Line Voltage |
Current |
Frequency |
Power Factor |
Active Power |
Total Reactive Power |
Total Apparent Power |
Each Phase Power Factor |
|
Each Phase |
Apparent Power |
Active Energy |
Reactive Energy |
⑨ 96×96 |
⑧ 80×80 |
⑦ 72×72 |
Communication Interface: RS485 |
4-Channel Switch Outputs |
4-Channel Switch Input |
4-Channel Analog Output |
Harmonic |
||
SFS-□S3-3E |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
● |
● |
√ |
|
|
+ |
|
|
|
|
|
SFS-□SY-3E |
● |
● |
● |
● |
● |
● |
● |
|
|
● |
● |
● |
● |
● |
√ |
|
|
+ |
|
|
|
|
|
SFN-□S3-3E |
● |
● |
● |
● |
● |
|
|
|
|
|
|
|
● |
● |
√ |
|
√ |
+ |
|
|
|
|
|
SFN-□SY-3E |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
√ |
√ |
√ |
+ |
|
|
|
|
|
SFN-□S3-3E+4DO |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
● |
● |
√ |
|
|
+ |
+ |
|
|
|
|
SFN-□SY-3E+4DO |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
√ |
|
|
+ |
+ |
|
|
|
|
SFN-□S3-3E+4DI |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
● |
● |
√ |
|
|
+ |
|
+ |
|
|
|
SFN-□SY-3E+4DI |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
√ |
|
|
+ |
|
+ |
|
|
|
SFN-□S3-3E+4AO |
● |
● |
● |
● |
● |
● |
● |
|
|
|
|
|
● |
● |
√ |
|
|
+ |
|
|
+ |
|
|
SFN-□SY-3E+4AO |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
● |
● |
● |
|
√ |
|
|
+ |
|
|
+ |
|
|
SFN-□SY-3E+H |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
● |
|
√ |
|
|
+ |
|
|
|
+ |
|












