Inquiry Now
Leave Your Message

Multifunctional LED Power Instrument: High-Precision Electrical Monitoring from China Suppliers and Factory

The multifunctional power instrument, crafted by leading China suppliers, is engineered to meet the electrical monitoring needs of power distribution systems. This high-precision device effectively measures essential electrical parameters, including three-phase voltage, three-phase current, active power, reactive power, frequency, power factor, and four-quadrant energy. The long-lasting LED display clearly presents both measurement data and operational information regarding the network system. Featuring an RS485 communication interface that utilizes the MODBUS_RTU protocol, this instrument ensures seamless data transmission. Additionally, with four programmable keys on the panel, users can conveniently switch and customize parameters, providing exceptional flexibility. Trust in our factory to deliver innovative solutions for your power monitoring requirements

    Product Overview

    Many kinds of extended function modules for choosing: four-channel analog quantity (0~20mA/4~20mA) output can realize the transmitting output function of electrical quantity; four-channel switching value input and four-channel switching value output to realize the local or long-range switch signal monitoring and control output function (function of "remote signaling" and "remote control"). The instrument can directly replace conventional power transmitter, measuring indicating instrument, electric energy measuring instrument and the related auxiliary unit. With modular structural design, users can choose the most economical functional configuration according to the actual requirement, which is highly cost-effective.

    It is widely used in occasions of energy management systems, supply and distribution network automation, district power control and complete sets of switchgear. It has the advantages of convenient installment and maintenance, simple wiring, small quantity, programmable input parameters and capable of the network with different PLC, industry control computer communications.

    • โšก4-Channel Analog Output: 0~20mA / 4~20mA for electrical quantity transmitting
    • ๐Ÿ”€Switching Value I/O: 4-channel input & 4-channel output for remote signaling & control
    • ๐Ÿ”ŒDirect Replacement: Replaces conventional power transmitters & energy measuring instruments
    • ๐ŸญWide Applications: Energy management, distribution automation, switchgear, district power control
    • ๐Ÿ”—Network Compatible: Works with PLC & industrial control computers via RS485 / MODBUS-RTU
    • ๐Ÿ’กModular Design: Cost-effective, programmable, flexible configuration

    Technical Parameters

    Technical Parameters Index
    Input Network Three-phase three-wire, three-phase four-wire
    Voltage Rated value AC 0~500V
    Over load Consistent 1.2 times instantaneous, 2 times / 30s
    Consumption <0.5VA (each phase)
    Impedance >500kฮฉ
    Current Rated value AC 1A, 5A
    Over load Consistent: 1.2 times instantaneous, 2 times 1s
    Impedance <2mฮฉ
    Frequency 45โ€“65Hz
    Output Electric Energy Output mode Two-channel open-collector, optical coupling pulse output
    Pulse constant Active: 3200 imp/kWh
    Reactive: 3200 imp/kvarh
    Start On the condition of rated voltage, reference frequency and cosฯ†=1.0, when load operational current is 0.01In, it can start and measure the electric energy continuously.
    Creep When exciting 115% rated voltage and no current in the current circuitry, the instrument is with no electric energy accumulation and pulse output.
    Technical Parameters Index
    Output Communication Output mode RS485
    Protocol MODBUS_RTU
    Baud rate 1200, 2400, 4800, 9600
    Analog Quantity Channel quantity 4 channels
    Output mode 0โ€“20mA, 4โ€“20mA
    Load ability <400ฮฉ
    Switching Value Channel quantity 4 channels
    Output mode Normally open relay contact output
    Contact capability AC 240V / 2A
    Switching value input Four channel dry contact input modes
    Display mode LED (RED)
    Measuring Accuracy Voltage, Current ยฑ (0.5%FS + one digit)
    Active power, Reactive power ยฑ (0.5%FS + one digit)
    Frequency ยฑ 0.1Hz
    Power factor ยฑ 0.01PF
    Active energy ยฑ 0.5% (only for reference, not for meterage)
    Reactive energy ยฑ 1.0% (only for reference, not for meterage)
    Source Scope AC 220V, 50/60Hz
    Consumption <5VA
    Safety Withstand Voltage Input and source >2kV 50Hz / 1min
    Input and output >1kV 50Hz / 1min
    Output and source >2kV 50Hz / 1min
    Insulating resistance Any two of input, output, source, casing >20Mฮฉ
    Environment Temperature Operation: -10 ~ 50ยฐC
    Storage: -25 ~ 70ยฐC
    Humidity โ‰ค85%RH, free of wet and corrosive gas
    Elevation โ‰ค3000m
    Function & Shape / Model Measure & Display Shape Code
    (Figure Inside โ–ก)
    Selected Additional Functions
    Phase Voltage V Line Voltage Current Frequency Power Factor Active Power Total Reactive Power Total Apparent Power Each Phase Power Factor Each Phase Apparent Power Active Energy Reactive Energy โ‘จ 96ร—96 โ‘ง 80ร—80 โ‘ฆ 72ร—72 Communication RS485 4-ch Switch Outputs 4-ch Switch Inputs 4-ch Analog Output Harmonic
    SFS-โ–กS3-3E โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš +
    SFS-โ–กSY-3E โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš +
    SFN-โ–กS3-3E โ— โ— โ— โ— โ— โ— โ— โˆš โˆš +
    SFN-โ–กSY-3E โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš โˆš โˆš +
    SFN-โ–กS3-3E+4DO โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กSY-3E+4DO โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กS3-3E+4DI โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กSY-3E+4DI โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กS3-3E+4AO โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กSY-3E+4AO โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +
    SFN-โ–กSY-3E+H โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โ— โˆš + +

    Frequently Asked Questions (FAQ)

    โ“What communication protocols does this power meter support?
    The instrument supports RS485 communication interface with MODBUS-RTU protocol. It supports baud rates of 1200, 2400, 4800, and 9600 bps, making it compatible with a wide range of PLCs and industrial control computers.
    โ“What are the available analog output options?
    The instrument provides 4-channel analog output with selectable modes of 0โ€“20mA or 4โ€“20mA. The load ability is less than 400ฮฉ, making it suitable for transmitting electrical quantity signals to remote monitoring systems.
    โ“What panel sizes are available for this instrument?
    The instrument is available in three standard panel sizes: 96ร—96mm (Shape Code โ‘จ), 80ร—80mm (Shape Code โ‘ง), and 72ร—72mm (Shape Code โ‘ฆ). Users can select the appropriate size based on their installation requirements.
    โ“What is the measuring accuracy for voltage, current, and power?
    The instrument achieves ยฑ(0.5%FS + one digit) accuracy for voltage, current, active power, and reactive power measurements. Frequency accuracy is ยฑ0.1Hz, power factor accuracy is ยฑ0.01PF, and energy measurement accuracy is ยฑ0.5% for active energy and ยฑ1.0% for reactive energy (for reference only, not for billing/meterage).
    โ“What switching value input and output options are supported?
    The instrument supports 4-channel dry contact switching value input and 4-channel normally open relay contact output (AC 240V / 2A). These enable local or remote switch signal monitoring and control, fulfilling "remote signaling" and "remote control" functions.
    โ“What are the power supply requirements and operating environment conditions?
    The instrument requires an AC 220V, 50/60Hz power supply with a consumption of less than 5VA. It operates in temperatures from -10ยฐC to 50ยฐC, with storage temperatures from -25ยฐC to 70ยฐC. Humidity should be โ‰ค85%RH with no corrosive gas, and the installation elevation should not exceed 3000m.