High-Precision Power Factor Meters from China Suppliers & Factory for Real-Time Energy Monitoring
Product Overview
The meter supports a wide, scalable measurement range to accommodate low, medium, and high-power system loads, with seamless unit switching between watts (W), kilowatts (kW), and megawatts (MW):
- This broad range enables precise monitoring of small-scale loads (e.g., control circuits, lighting systems), industrial machinery (e.g., motors, compressors), and large-scale power generation/transmission systems (e.g., generators, substations).
Designed to measure reactive power (the power stored and released by inductive/capacitive components in the system), the meter features a scalable range with unit switching between vars (Var), kilovars (kVar), and megavars (MVar):
- Critical for applications such as power factor correction, load balancing, and grid stability monitoring, where reactive power management is essential to minimize energy waste and equipment stress.
The meter provides high-resolution power factor measurement across the full spectrum of capacitive, unity, and inductive load conditions, with clear differentiation between capacitive (C) and inductive (L) power factors:
- Capacitive Range (0.000 C ~ 1.000): Applies to loads that supply reactive power to the grid (e.g., capacitor banks, over-excited synchronous motors).
- Unity Point (1.000): Represents ideal load conditions where voltage and current are perfectly in phase, minimizing reactive power loss.
- Inductive Range (1.000 ~ 0.000 L): Applies to loads that draw reactive power from the grid (e.g., induction motors, transformers, fluorescent lighting).
- The 0.001 resolution ensures precise monitoring of subtle power factor changes, supporting targeted power factor correction strategies.
All meters are calibrated to strict accuracy standards, ensuring reliable, traceable measurements even under varying load and environmental conditions:
Technical Parameters
| Function & Shape / Model | Measure & Display | Shape Code (Figure Inside) | Selected Additional Functions | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1-Phase Power Factor |
1-Phase Active Power |
3-Phase Power Factor |
3-Phase Active Factor |
⑨ 96×96 |
⑧ 80×80 |
⑦ 72×72 |
⑤ 96×48 |
④ 48×48 |
||
| SFN-□K1-H | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-P | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-3H | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-3P | ● | √ | √ | √ | ||||||
| SFN-□K1-H+RS | ● | √ | √ | √ | √ | RS485 | ||||
| SFN-□K1-P+RS | ● | √ | √ | √ | √ | RS485 | ||||
| SFN-□K1-3H+RS | ● | √ | √ | √ | √ | RS485 | ||||
| SFN-□K1-3P+RS | ● | √ | √ | √ | RS485 | |||||