High-Precision Power Factor Meters from China Suppliers and Factory for Real-Time Monitoring in AC Systems
Product Overview
1.1 Measuring Range
Measurement Range: 0 ~ 9999 W ~ 9999 kW ~ 9999 MW
Supports a wide, scalable measurement range to accommodate low, medium, and high-power system loads, with seamless unit switching.
Enables precise monitoring of small-scale loads (e.g., control circuits, lighting systems), industrial machinery (e.g., motors, compressors), and large-scale power generation/transmission systems (e.g., generators, substations).
Measurement Range: 0 ~ 9999 Var ~ 9999 kVar ~ 9999 MVar
Designed to measure reactive power stored and released by inductive/capacitive components in the system.
Critical for applications such as power factor correction, load balancing, and grid stability monitoring, where reactive power management is essential to minimize energy waste and equipment stress.
Measurement Range: 0.000 C ~ 0.500 C ~ 1.000 (unity) ~ 0.500 L ~ 0.000 L
- Capacitive Range (0.000 C ~ 1.000): Applies to loads supplying reactive power to the grid (e.g., capacitor banks, over-excited synchronous motors).
- Unity Point (1.000): Represents ideal load conditions where voltage and current are perfectly in phase.
- Inductive Range (1.000 ~ 0.000 L): Applies to loads drawing reactive power from the grid (e.g., induction motors, transformers, fluorescent lighting).
The 0.001 resolution ensures precise monitoring of subtle power factor changes, supporting targeted power factor correction strategies.
1.2 Accuracy Rating
Accuracy: ±0.5% Full Scale (FS) ± 1 digit
The ±0.5% FS tolerance ensures high accuracy across the entire measurement range, while the ±1 digit error accounts for minor digital display quantization effects.
Accuracy: ±1.0% Full Scale (FS) ± 1 digit
Optimized for reactive power measurement, with a balance of accuracy and cost-effectiveness for standard industrial monitoring applications.
Accuracy: ±0.01
Delivers precise power factor readings with a maximum error of 0.01, critical for verifying compliance with utility power factor regulations and optimizing energy efficiency.
Technical Parameters
| Function & Shape/Model | Measure & Display | Shape Code (Figure Inside) | Selected Additional Functions | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1-phase power factor | 1-phase active power | 3-phase power factor | 3-phase active factor | ⑨ 96×96 | ⑧ 80×80 | ⑦ 72×72 | ⑤ 96×48 | ④ 48×48 | Communication interface: RS485 | |
| SFN-□K1-H | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-P | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-3H | ● | √ | √ | √ | √ | √ | ||||
| SFN-□K1-3P | ● | √ | √ | √ | ||||||
| SFN-□K1-H+RS | ● | √ | √ | √ | √ | 十 | ||||
| SFN-□K1-P+RS | ● | √ | √ | √ | 九 | 十 | ||||
| SFN-□K1-3H+RS | ● | V | √ | √ | √ | 十 | ||||
| SFN-□K1-3P+RS | ● | √ | √ | A | √ | 十 | ||||