Product Overview
Many kinds of extended function modules for choosing: one-channel analog quantity (0~20mA/4~20mA) output can realize the transmitting output function of electrical quantity; two-channel switching value input and two-channel switching value output to realize the local or long-range switch signal monitoring and control output function (function of "remote signaling" and "remote control"). The instrument can directly replace conventional power transmitter, measuring indicating instrument, electric energy measuring instrument and the related auxiliary unit. With modular structural design, users can choose the most economical functional configuration according to the actual requirement, which is highly cost-effective.
Technical Parameters
| Category | Parameter Item | Technical Specifications |
|---|---|---|
| Input | Network Type | Single phase |
| Voltage Rated Value | AC 0~500V | |
| Voltage Overload & Impedance | Continuous: 1.2x | Instantaneous: 2x / 30s | Impedance: >500kΩ | Consumption: <0.5VA (each phase) | |
| Current Rated Value | AC 1A, 5A | |
| Current Overload & Impedance | Continuous: 1.2x | Instantaneous: 2x / 1s | Impedance: <2mΩ | |
| Frequency | 45-65Hz | |
| Display Mode | LED (Red) | |
| Output | Communication Interface | RS485 | Protocol: MODBUS-RTU | Baud rate: 1200, 2400, 4800, 9600 |
| Analog Quantity Output | 1 Channel | 0~20mA, 4~20mA | Load capability: ≤400Ω | |
| Switching Value Output | 2 Channels normally open relay contact | Capacity: AC 250V/5A, DC 30V/5A | |
| Switching Value Input | 2 Channels | |
| Measuring Accuracy | Voltage & Current | ±(0.5%FS + 1 digit) |
| Active / Reactive Power | ±(0.5%FS + 1 digit) | |
| Frequency & Power Factor | Frequency: ±0.1Hz | Power factor: ±0.01PF | |
| Active Energy | ±0.5% (Reference measurement) | |
| Reactive Energy | ±1.0% (Reference measurement) | |
| Power Supply | Voltage Scope | AC 220V, 50/60Hz |
| Power Consumption | <5VA | |
| Safety Insulation | Withstand Voltage | Input & Source: >2kV 50Hz/1min | Input & Output: >1kV 50Hz/1min | Output & Source: >2kV 50Hz/1min |
| Insulating Resistance | Input, output, source, casing (any two points): >20MΩ | |
| Environment | Temperature Range | Operation: -10°C ~ 50°C | Storage: -25°C ~ 70°C |
| Relative Humidity | <85%RH, free of condensation and corrosive gas | |
| Operating Elevation | ≤3000m |